HXLPE acetabular liners have 40% lower wear rate compared to UHMWPE at 2 years after THA
54 patients with primary hip osteoarthritis schedule to undergo total hip arthroplasty were randomized to receive either highly cross-linked polyethylene (HXLPE) or standard ultra high-molecular-weight polyethylene (UHMWPE) liners. HXLPE acetabular liners have 40% lower wear rate compared to UHMWPE at 2 years after THA.